Class A is the strongest ASTM E108 label, but it describes one tested assembly on a defined deck. Match the listing to your slope and deck type. Local building and wildfire rules may require more than the product sheet states. Keep the test report with the contract.
Sections8
Roof fire ratings sort roof coverings into Class A, Class B, Class C, or no class when the material fails the lightest tests. Class A is the strongest defined class under ASTM E108, which building codes often cite as UL 790. The label describes a standard test, not a promise for every real fire.
The ASTM E108 standard measures how roof coverings respond to simulated outside fire and wind. A 1981 NIST report on ASTM E108 notes the same method is also known as NFPA 256 and UL 790. Use the roofing materials guide to compare coverings, then check each product's own fire record.
What roof fire ratings measure
ASTM E108 applies to roof coverings on combustible or noncombustible decks when installed as intended. The standard includes intermittent flame, spread of flame, burning brand, and flying brand tests. Its scope states that Class A methods target severe outside exposure, Class B moderate exposure, and Class C light exposure.
The tests do not show how the same roof will act in every wildfire or interior fire. ASTM also states the methods do not measure fire resistance when flames start inside the building. Treat the class as one fact in a larger wildfire or code decision, not a stand-in for a full site review.
Class A, B, and C at a glance
The table below quotes spread limits from NIST's 1981 summary of ASTM E108 in a solar-collector research report. Exposure times match the 2024 ICC-ES description of the spread-of-flame test.
| Class | Test severity | Max spread of flame (NIST 1981) |
|---|---|---|
| A | Severe outside exposure | 6 ft (1.8 m) |
| B | Moderate exposure | 8 ft (2.4 m) |
| C | Light exposure | 13 ft (4.0 m) |
Scroll for more →
ICC Evaluation Service states that spread-of-flame tests for Classes A and B run for ten minutes, or until the flame permanently recedes from the maximum spread point, whichever is shorter. Class C runs for four minutes under the same conditions. ICC-ES says a Class needs a minimum of two roof decks to pass the performance requirements when tested in sequence.
How the burning brand and flame tests work
NIST's 1981 summary states Class A uses a 12 x 12 in Douglas fir brand and Class B uses a 6 x 6 in brand. Class C brands use small white pine pieces. Class A uses one brand in that summary, Class B uses two brands, and Class C uses 25 brands.
Pass rules for burning brand and intermittent flame tests match in NIST's summary: no glowing brands continue on the floor, the deck stays covered, and there is no flaming on the underside of the deck. Intermittent flame uses a 1400 °F gas flame for Classes A and B and 1300 °F for Class C, per NIST.
These details describe laboratory conditions. Your inspector or roofer still needs the listing for the product actually installed.
ASTM E108 includes a flying brand test. Its scope states that Class A coverings should not present a flying-brand hazard. ICC-ES notes that the flying brand test applies when the covering may break into flaming pieces. ICC-ES maintains a 12-mph air flow until flame, glow, and smoke end on the surface to see whether flying brands develop.
Deck type changes which tests apply
ICC Evaluation Service notes that the spread-of-flame test applies when a covering is not limited to noncombustible decks. The burning brand test also applies when the covering may be used over combustible wood decks.
Name your deck type in the quote so the class you buy matches the tests for that use. Products that fail every Class C method remain unrated for this standard. They should not be compared with Class A bids without a new listing. The DOE metal roof guide states that fire-resistance-rated underlayment may be required by local jurisdictions in wildfire areas.
Covering class versus listed assembly
A package may list Class A for the covering alone or only when paired with named underlayment, fasteners, or insulation. IBHS warns that a metal panel can show Class A while the applicable code may still require additional fire provisions for occupancy or construction type.
Before installation:
- Ask which ASTM E108 class is printed for the exact SKU on your order.
- Request the installation instructions that reproduce the tested assembly.
- Confirm the deck, slope, and underlayment in the quote match that listing.
- Keep the label and report with warranty and permit files.
The metal roof durability guide explains why attachment layers affect wind and hail performance on metal roofs.
Materials often associated with each class
ASTM assigns the class from test results, not from material names alone. Still, some families commonly reach Class A when listed correctly.
IBHS Roof 101 describes a fiberglass mat in asphalt shingles that helps meet Class A fire requirements for that product type. The IBHS low-slope metal guide states metal panel roofs are classified Class A to meet model code fire provisions. Always read the current product report instead of guessing from the material family.
Wildfire areas and metal roofs
The DOE Building America metal roof guide calls metal roofing fire-resistant and says metal roofs are generally considered a fire-resistant covering in wildfire-prone areas. That helps, but the guide also notes that the full assembly, deck, and underlayment affect whether the listed class applies.
When comparing metal in fire-prone regions, pair this page with standing seam metal roof cost for scope on seams and fasteners. Ask the roofer how the proposed assembly matches the Class A listing and how valleys and edges are detailed.
Your permit office or plan reviewer names the class required for your address. Keep the approved plan and the product listing together so a future re-roof uses the same test record.
Check fire ratings before you sign
Use this sequence when a contractor cites Class A:
- Collect the product data sheet, evaluation report, or label that shows the ASTM E108 or UL 790 class.
- Verify the class covers your deck type and roof slope.
- Compare underlayment, insulation, and attachment items to the listed assembly.
- Ask how changes such as skylights or solar mounts affect the listing, if the standard scope allows those accessories.
- File the records next to the contract before work starts.
A lower bid without matching test records is not the same product, even when both roofs use metal or asphalt shingles.
Quick answers
What is the highest roof fire rating class?
Class A is the highest class in ASTM E108. Class B is moderate and Class C is light. A covering that fails the Class C methods is unrated.
Is metal roofing always Class A?
IBHS states that metal panel roofs are classified as Class A to meet model code fire provisions, though the applicable code may require a further fire-rated roof. The DOE wildfire guide notes that metal roofs often need a noncombustible deck or fire-resistant underlayment for the assembly to qualify as Class A. Ask for the listed assembly on your order.
Does a Class A label make the whole house fire-safe?
No. ASTM states its roof tests measure outside exposure on the covering and do not determine fire resistance when fire starts inside the building.
Can wood shakes earn a Class A rating?
[ICC Evaluation Service](https://icc-es.org/product-testing-2/astm-e108/) says that when treated wood shakes are in the test sample, the flying-brand air current rises to 18 ± 0.75 mph. Read the listing for the exact product.
Is a roof fire class the same as hail impact class?
No. Fire classes come from ASTM E108. Hail impact classes such as UL 2218 use a different standard and test.
Where do I verify the rating on a bid?
Request the label, test report, or evaluation report that states the Class A, B, or C result for the exact covering and deck type in the quote.